Reliability of B-mode ultrasound and shear wave elastography in evaluating sacral bone and soft tissue characteristics in young adults with clinical feasibility in elderly - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of Tissue Viability Année : 2022

Reliability of B-mode ultrasound and shear wave elastography in evaluating sacral bone and soft tissue characteristics in young adults with clinical feasibility in elderly

Résumé

Background: Physiologic aging is associated with loss of mobility, sarcopenia, skin atrophy and loss of elasticity. These factors contribute, in the elderly, to the occurrence of a pressure ulcer (PU). Brightness mode ultrasound (US) and shear wave elastography (SWE) have been proposed as a patient-specific, bedside, and predictive tool for PU. However, reliability and clinical feasibility in application to the sacral region have not been clearly established. Method: The current study aimed to propose a simple bedside protocol combining US and SWE. The protocol was first tested on a group of 19 healthy young subjects by two operators. The measurements were repeated three times. Eight parameters were evaluated at the medial sacral crest. Intraclass Correlation Coefficient (ICC) was used for reliability assessment and the modified Bland Altman plot analysis for agreement assessment. The protocol was then evaluated for clinical feasibility on a healthy older group of 11 subjects with a mean age of 65 ± 2.4 yrs. Findings: ICC showed poor to good reliability except for skin SWE and hypodermis thickness with an ICC (reported as: mean(95%CI)) of 0.78(0.50-0.91) and 0.98(0.95-0.99) respectively. No significant differences were observed between the young and older group except for the muscle Shear Wave Speed (SWS) (respectively 2.11 ± 0.27 m/s vs 1.70 ± 0.17 m/s). Interpretation: This is the first protocol combining US and SWE that can be proposed on a large scale in nursing homes. Reliability, however, was unsatisfactory for most parameters despite efforts to standardize the protocol and measurement definitions. Further studies are needed to improve reliability.
Fichier principal
Vignette du fichier
IBHGC_JTV_2022_Abou KARAM.pdf (1.63 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03584731 , version 1 (22-02-2022)

Identifiants

Citer

Maher Abou Karam, Ekaterina Mukhina, Nils Daras, Isabelle Rivals, Helene Pillet, et al.. Reliability of B-mode ultrasound and shear wave elastography in evaluating sacral bone and soft tissue characteristics in young adults with clinical feasibility in elderly. Journal of Tissue Viability, 2022, ⟨10.1016/j.jtv.2022.02.003⟩. ⟨hal-03584731⟩
438 Consultations
83 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More